When a T-slot nut drawing, specification table and quotation disagree, do not choose the value that makes the order easiest to place. Keep the affected item pending clarification. The required outcome is a documented agreement about the exact variant and dimension, carried consistently into the accepted order documents.

Preserve both versions of the conflict

Save each source with its filename or page reference, date and revision if available. Include enough surrounding information to identify the product and table row. A cropped number without the variant heading may conceal that two different items are being compared.

Record the original values exactly, including units. If a source has no revision, write “revision not stated” rather than inventing one. Retain the original reference even if the supplier subsequently replaces the online file.

Establish whether the values describe the same feature

Check the full variant code, selected thread, profile-series row and drawing applicability. Follow the dimension endpoints: an overall height and a body thickness are different features even when both are casually called thickness. Dimension letters also need their own drawing context; a shared letter is not proof of a shared definition.

Check units and whether each source presents a nominal dimension, an explicit limit or a measured observation. Keep any unit conversion visible beside the original. Do not explain away a discrepancy as rounding or tolerance unless the applicable specification supports that explanation. The drawing guide covers the underlying drawing-to-row check.

Open a short discrepancy record

Open a short discrepancy record
Record fieldEntry to capture
Affected itemComplete variant and order or quotation line
FeatureDimension label plus identified endpoints or marked view
Source AValue, unit, file or page, revision and date
Source BValue, unit, file or page, revision and date
Practical dependencyWhich interface or purchasing decision remains unresolved
Required resolutionApplicable value and document; explanation of the other source
StatusPending, clarified or approved; reviewer and date

Use a separate row or record for each disputed feature. This prevents a general “drawing confirmed” response from closing several questions that received different or incomplete answers.

Request an explicit supplier resolution

For [complete variant], [feature] is shown as [value and unit] in [source A] and [value and unit] in [source B]. Please confirm which applies to the quoted item, explain the discrepancy and provide the corrected document or written clarification tied to this variant. Please identify any effect on the quoted supply.

The newest date alone is insufficient if the document does not apply to the offered variant. Likewise, a sample measurement records an observation; it does not automatically establish the specified dimension or permitted variation. If the answer is only “standard size,” keep the question open.

Close the conflict in every affected order reference

Have the responsible buyer or technical reviewer accept the clarified requirement. Update the quotation attachment, drawing reference and item record together, preserving superseded files as history. Ask the supplier to acknowledge the same reference before approval. For unresolved fit-critical information, retain a requires-verification status rather than accepting an undocumented assumption.

Any sample check should address the agreed question and acceptance basis; it does not replace document correction. Use the sample approval guide when a physical check is part of the decision. Close the discrepancy only when the accepted requirement and the proposed supply refer to the same resolved information.

Share the conflicting references

Send both sources and mark the dimension in question; include the complete variant code if known.